SLYD
Read first

The 5-step pipeline.

How energy turns into a deployed, financed, offtake-matched cluster, and what SLYD does at every step.

How SLYD works →
Hardware

New and recovered GPU systems.

NVIDIA and AMD systems through documented manufacturer and qualified channel supply, with financing and deployment coordinated on the same platform.

Explore GPU hardware →
Marketplace

Compute, hardware, and power in one book.

Browse available GPU capacity by accelerator, configuration, region, and price, or bring supply to qualified demand.

Open marketplace →
Pre-qualify

Start with an indicative structure.

Tell us deal size, structure, and offtake. Any range is preliminary and subject to underwriting, diligence, and documentation.

Open Configure →
From the blog

GPU market trends and deployment playbooks.

Infrastructure best practices, hardware comparisons, and industry analysis from the SLYD team.

Read the blog →

Library

Manufacturer family

GIGABYTE AI servers and GIGAPOD systems

GIGABYTE publishes GIGAPOD as a scalable unit with two very different physical shapes depending on cooling. That makes it a useful worked example of how the cooling decision changes rack count, power per rack, and what the site has to provide.

What are GIGABYTE AI servers and GIGAPOD?

GIGABYTE offers GPU servers and GIGAPOD rack-scale systems for AI and HPC deployments. Buyers should evaluate the exact server or pod configuration, accelerator platform, rack density, network, storage, power, cooling, site readiness, support, and commercial terms.

GIGAPOD architecture

Two configurations, same compute, different buildings

GIGABYTE publishes GIGAPOD in air-cooled and liquid-cooled configurations with different servers and different power densities. Comparing them side by side is the clearest illustration of why cooling is a facility decision rather than a preference.

Source: GIGABYTE GIGAPOD solution pages, reviewed 18 August 2026. Every figure below is stated by GIGABYTE for the configuration named in its column and does not describe the GIGABYTE portfolio generally.
Attribute Air-cooled GIGAPOD Liquid-cooled GIGAPOD
Server 8U G893-series 4U G4L3-series with cold plates on all eight GPUs and two CPUs
Power per rack, as published Rack support for 50 kW of IT hardware power 100 kW per rack
GPUs per rack, as published Published as four servers per rack alongside switches and other components Up to eight servers and 64 GPUs per rack
Scalable unit, as published Nine air-cooled racks Five liquid-cooled racks
Facility requirement Air handling and containment sized for the rack load Facility water loop, heat rejection, water quality management, and a loop maintenance model

GIGABYTE describes GIGAPOD as scaling from one GPU server up to eight racks with 32 GPU nodes, a total of 256 GPUs. Where a figure here has an "up to" or a named configuration attached, that qualifier is part of the fact and should stay attached when the figure is reused.

How to read these numbers

A configuration figure is not a portfolio figure

GIGABYTE states that GIGAPOD HPC uses a full-system direct liquid cooling solution with integrated piping achieving up to 91 percent system heat coverage, validated for up to 105 kW per rack.

That is a strong, specific, useful claim, and it belongs to GIGAPOD HPC. It does not describe every GIGABYTE server, it does not describe direct liquid cooling in general, and it is not a SLYD engineering result. The same discipline applies to the 50 kW and 100 kW rack figures above: they are what GIGABYTE publishes for those GIGAPOD configurations, not a design point to apply to an arbitrary rack.

When a manufacturer figure is used in a design, carry the configuration name, the qualifier, and the source date with it. The cooling page and the power page cover what still has to be engineered for the specific site regardless of what the manufacturer publishes.

Who provides what

GIGABYTE products and SLYD process are separate things

GIGABYTE

Manufacturer products and relationships

System designs, GIGAPOD architecture, cooling technology, and any manufacturer technology relationship are GIGABYTE's. A relationship between GIGABYTE and a component vendor says nothing about SLYD.

SLYD

Sourcing process

SLYD evaluates a stated requirement, identifies which documented sourcing paths are available for the requested system, and confirms configuration, seller authority, provenance, condition, availability, and commercial terms for the specific transaction.

SLYD is an authorized reseller for GIGABYTE / Giga Computing. Configuration availability and lead times are quoted at time of order. SLYD makes no claim of distributor status, and does not state that any current GIGABYTE system is available through SLYD.

What we need from you

To request a configuration

  • Workload and scale
  • Target GPU count
  • Deployment location
  • Available power per rack
  • Whether facility water is available
  • Rack space and floor loading
  • Network and storage requirements
  • Target timeline
  • Compliance and export constraints
  • Capital structure preference
FAQ

GIGABYTE and GIGAPOD questions

What is GIGAPOD?

GIGAPOD is GIGABYTE's rack-scale AI system. GIGABYTE describes the scalable unit as either nine air-cooled racks or five liquid-cooled racks, and describes GIGAPOD scaling to eight racks with 32 GPU nodes, a total of 256 GPUs. The cooling choice changes the rack count for the same amount of compute.

How do air-cooled and liquid-cooled GIGAPOD configurations differ?

They use different servers and different power densities. GIGABYTE states that the air-cooled configuration uses an 8U G893-series server and that each rack requires support for 50 kW of power for the IT hardware. The liquid-cooled configuration uses a 4U G4L3-series server with cold plates on all eight GPUs and two CPUs, allowing up to eight servers and 64 GPUs per rack at 100 kW per rack.

What power does a GIGAPOD rack require?

It depends on the configuration, and GIGABYTE publishes both. The air-cooled GIGAPOD configuration is described as requiring rack support for 50 kW of IT hardware power, and the liquid-cooled configuration as requiring 100 kW per rack. Those are GIGABYTE figures for those named configurations and are not a general GIGABYTE rack figure.

What heat coverage does GIGABYTE publish for direct liquid cooling?

GIGABYTE states that GIGAPOD HPC uses a full-system direct liquid cooling solution with integrated piping achieving up to 91 percent system heat coverage, validated for up to 105 kW per rack. That figure belongs to the GIGAPOD HPC configuration specifically and should not be applied to other GIGABYTE systems or to direct liquid cooling generally.

Does GIGABYTE offer NVIDIA Grace Blackwell rack systems?

GIGABYTE publishes an NVIDIA GB300 NVL72 GIGAPOD AI direct-liquid-cooling rack-scale solution. As with any rack-scale platform, the facility requirements come from the exact configuration quoted, and they should be confirmed against the site before the system is selected.

Is SLYD an authorized GIGABYTE reseller?

SLYD is an authorized reseller for GIGABYTE / Giga Computing. Configuration availability and lead times are quoted at time of order. SLYD makes no claim of distributor status on this site. A manufacturer's own technology relationships are that manufacturer's, and they are not SLYD relationships. SLYD evaluates a stated buyer requirement and identifies which documented sourcing paths are available for the requested system.

Does a GIGABYTE system named here mean SLYD can supply it?

No. GIGABYTE system names and figures are reproduced from GIGABYTE's published materials to explain the architecture choices available. Whether a specific configuration can be obtained, in what quantity, for what geography, and on what terms is confirmed at the transaction level.

What information is needed to request a GIGABYTE configuration?

The workload and scale, target GPU count, deployment location, available power per rack, whether the site can supply facility water for direct liquid cooling, rack space and floor loading, network and storage requirements, target timeline, and any compliance or capital constraints.

Sources for the GIGABYTE information on this page

Rack counts, power figures, node counts, and heat coverage figures are GIGABYTE's, reproduced with the exact configuration they apply to. They are not SLYD engineering results and are not SLYD guarantees of configuration, performance, or availability. GIGABYTE and GIGAPOD are trademarks of their owner and are used here descriptively.

Request a GIGABYTE configuration

Start with GPU count, available power per rack, and whether facility water exists. Those settle which GIGAPOD configuration is even possible at the site.